Inglis refrigerators share engineering with Whirlpool models. Adaptive defrost control board failures are the call we get most: the board stops initiating defrost cycles, ice builds on the evaporator coils, and cooling drops off. Defrost heater open circuits and bi-metal thermostat failures do the same thing. Evaporator fan motor wear causes uneven shelf temperatures. Compressor start relay failures stop the compressor from engaging. We carry common Inglis fridge parts for same-day repair.